Back
Home > Electrochemical Cells >In Situ Raman Spectroscopy Electrochemical Cell 5ml Three Electrode System

In-situ Raman spectroscopy Electrochemical cell 5ml three-electrode system

SKU: CIR251A1

Special Price C$2,438.95

Regular Price: C$2,438.95

Description

• Fits all major brands of potentiostats
• This is a customized item, invalid for refund or exchange.
• Size: 5ml

In-situ Raman spectroscopy electrochemical cell is designed and manufactured for studying the in-situ spectra and morphology changes of electrode materials in electrochemical experiments. The working electrode is placed directly under the see-through window, so that the optical instrument can detect the working electrode from the quartz light window above the cell body. Commonly used instruments include optical microscopes, infrared microscopes, X-ray spectrometers, confocal Raman spectrometers, etc.

Our Recommendations

Product Details

characteristic:

1.The main body of the in-situ Raman cell is made of polytetrafluoroethylene material, which is made by meticulous crafting.

2.The size of the cell body is 80*80*22mm.The internal electrolyte solution part is a space of φ25*10mm, and the volume is 5ml.

3.The Raman cell is equipped with JGS2 quartz plate, the size of the quartz plate is φ41*1mm. The spectral application range of JGS2 optical quartz glass is 220-2500nm.

4.The Raman cell can be quickly assembled and disassembled, and it is easy to clean.

Customized requirements:

1.5 ml volume of the cell with a three-electrode system

2.No inlet/outlet holes

3.One φ0.5*100mm Pt ring counter electrodes

4.One φ0.5*37mm Pt wire reference electrodes

5.Two φ6*70mm Ag/AgCl reference electrodes

6.The PTFE tapered sealing plug, instead of the fluorine rubber O-ring

7.The PEEK replaceable sheet electrode holder with titanium sheet as the conductive substrate

8.10 sheets of soft expanded PTFE gaskets

NOTICE:

1.This is a customized item, we can't offer any refund or exchange. If you have any questions before purchasing, please feel free to communicate with us.

2.DekResearch's in-situ Raman spectroscopy electrochemical cell is basically suitable for various types of optical microscopes and Raman spectrometers in the world. When the focus distance of the instrument is different, please be sure to contact our technical team in advance.

Product Includes:
1 * PTFE cell
1 * PEEK titanium sheet electrode holder
1 * φ0.5*37mm  pt wire electrode
1 * φ0.5*100mm Pt ring counter electrode
2 * φ6*70mm Ag/AgCl reference electrode
1 * suction cup
1 * Nylon hand screw accessories
5 * φ41*1mm quartz light window
6 * PEEK anti-corrosion sealing screw and fluorine rubber O-ring
10 * PTFE tapered sealing plug
10 * Soft expanded PTFE gaskets
30 * light window sealing fluorine rubber gasket

References:

NEED HELP? CONTACT US

Call Toll-Free +1 (800) 972-7086

Email Us:

    Shipping
  • Standard Shipping: 5-7 Business days
  • DHL/Fedex Express Shipping: 2-5 Business days

PAYMENT

  • Write The First Review Now
    1. How do you rate this product?*
    2. Quality
    3. Value
    4. Price
    5. Support
    6. Overall
    Nickname* Summary of your Review*
    Review*
page: | more
if you need customization help, pls contact us via: here

PRODUCT RELATED

Q.
How to choose ordinary electrochemical cell and sealed electrochemical cell?
A.
Regardless of the user's tightness requirements for the actual test, the sealed electrochemical cell is the first choice. The sealed electrolytic cell is equipped with hollow sealing screws and fluorine rubber O-rings to install and seal the entire device, and then pass inert gas into the cell body to drive out the excess gas inside the cell body to realize the test of the system in an inert environment. If there is no requirement for tightness, no ventilation operation is required. However, if you choose an ordinary electrochemical cell, the related operations of the sealed electrolytic cell cannot be realized.
Q.
What volume of electrochemical cell is suitable to choose?
A.
The volume of the electrolytic cell should be selected moderately. If the volume is too large, the amount of solution will be too much, which is unnecessary. During electrochemical measurement, the electrode surface undergoes oxidation and reduction reactions, and some substances in the solution are reduced by participating in the electrode reaction. At the same time, some reaction products will dissolve into the solution. If the volume of the electrolytic cell is too small, the solution concentration will change significantly during the long-term steady-state measurement, which will eventually affect the experimental results. In most cases, the volume of 50ml and 100ml are more choices.
Q.
How to choose a working electrode?
A.
Common working electrodes include disk electrodes and replaceable electrode holders. The disk electrode is suitable as the base of the modified material, and it is modified to the base area of the disk electrode by mixing a membrane solution or the like with a powdered material. And if the material being studied is a sheet-like structure or the material can be modified to suitable materials such as conductive glass, carbon paper, carbon cloth, etc., it is more practical to choose a replaceable electrode clip.
Q.
How to choose a counter electrode?
A.
One of the important parameters of the counter electrode is its surface area. The counter electrode must have a large enough area to support the current conduction generated on the working electrode. Generally, the area of the counter electrode is 3-5 times the area of the working electrode. When choosing a disk electrode as the working electrode, platinum wire electrode is a good choice. When choosing sheet materials as working electrodes, platinum wire ring electrodes and platinum sheet electrodes are good choices.
Q.
How to choose a reference electrode?
A.
Generally speaking, calomel electrode or Ag/AgCl reference electrode is used in neutral system. Since the potential of calomel electrode changes greatly with temperature, when the temperature exceeds 70 degrees, it needs to be used with a salt bridge or replaced Use Ag/AgCl reference electrode. Hg2SO4 reference electrodes are generally suitable for sulfuric acid or sulfate systems. Hg/HgO reference electrodes are generally suitable for alkaline electrolyte solutions, of which the strong alkali system also needs to be used with a salt bridge, and the filling liquid in the salt bridge is consistent with the filling liquid of the reference electrode. The non-aqueous organic system needs to use a Ag/Ag+ reference electrode. When using a non-aqueous Ag/Ag+ reference electrode, the user needs to prepare a solution containing supporting electrolyte and silver ions (usually 10mM) and inject it into the reference electrode chamber. Due to shipping safety considerations, all reference electrodes are not filled with solution. Before use, the user needs to prepare an internal solution to fill it into the electrode.
Q.
Do you offer wholesale discounts?
A.
Yes, We have regular promo activities for all our customers. We do offer discounts to our customers who buy in bulk. We are appreciated for your inquire through E-mail. service@dekresearch.com.


SHOPPING GUIDE

Q.
Why the page does not jump during the process of placing order or adding the item to my cart?
A.
When you add the item to your cart or when you place the order, the page may not jump. There are some reasons for this situation. Maybe the speed of the browser you are using is slow, maybe the item you are adding is out of stock or you forget to choose the size of the item. You can change another browser to try, or check if you have selected the size of the item. If you also have problems please feel free to contact the online customer service to ask help, We will be happy to help you.
Q.
Do you have a physical store?
A.
In an effort to keep our prices low, we only do business online at the moment.
Q.
How can I use my coupon code?
A.
Generally it can be used in two ways. One is to fill it straight in "Discount Codes" textbox when you stay in shopping cart page .


ORDER GUIDE

Q.
How can I check my order information?
A.
For your convenience we highly encourage you to remember your order No.and provide it to us so that we can answer your any question accordingly. And the order No. is same as the invoice ID.Thank you for your support.
Q.
Why my payment was taken but the status of the order shows Pending?
A.
Generally speaking, after the order payment was completed the status of your order will show Processing, and will not change again till you receive your order. If it shows pending, please contact the customer service via email or online chat to check if your payment has been completed.
Q.
How to make sure that my order is finished?
A.
Once you had placed an order successfully, a confirmed letter including your order information would be provided by system automatically. We are very happy to answer your any questions by E-mail: service@dekresearch.com.

Returns Policy

SHIPPING POLICY
Destinations Delivery Option Cost* FREE SHIPPING Total Time
US
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
UK
Standard Shipping £19.95 on order £159+ 5-7 Businesss Days
Express £24.95 on order £249+ 2-5 Businesss Days
CA
Standard Shipping CA$19.95 on order CA$159+ 5-7 Businesss Days
Express CA$24.95 on order CA$249+ 2-5 Businesss Days
AU
Standard Shipping AU$19.95 on Order AU$159+ 5-7 Businesss Days
Express AU$24.95 on Order AU$249+ 2-5 Businesss Days
DE
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
FR
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
RU
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
MY
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
SG
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
PH
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
NZ
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
JP
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
BR
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
VN
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
    • In-situ Raman spectroscopy Electrochemical cell 5ml three-electrode system was successfully added to your shopping cart.